APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4483 Issued:2001-02-16
Revised:2013-02-08
Style 4483 Multiple-conductorcable using non-integral jacket

Rating90 deg C, 150 Vac, Cable flame, 60 deg C Oil.
InsulationLabeled and/or complying with manufacturer AWM Procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. The length of lay of the twisted conductors or groups is not specified.
ShieldOptional.
JacketExtruded Neoprene.
Diameter of the cable under jacketMinimum average thicknessMinimum thickness at any point
0.425 inches or less30 mils24 mils
0.426-0.700 inch45 mils46 mils
0.701-1.000 inch60 mils48 mils
1.001-1.500 inch80 mils62 mils
1.501-2.500 inch110 mils88 mils
2.501 inch and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024