Rating | 80 deg C, 600 Vac, Horizontal flame, Cable flame. |
|
Conductor | 32 AWG - 16 AWG solid or stranded round. May use same or mixed AWG size. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval or round cable construction. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. Insulated conductor is built with inner covering (optional), inner shield (optional), outer covering (optional), outer shield (optional), and jacket. |
|
Shield | Optional. Over and under covering |
|
Covering | Optional over conductors and inner shield- PVC, PTFE, PFA, FEP, ETFE or SBR, 5 mil minimum at any point, over the assembly. |
|
Jacket | Extruded SRB/NR |
| Diameter of cable under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inches or less* | 30 mils | 24 mils |
| 0.701-1.000 inches | 60 mils | 48 mils |
| 1.001-1.500 inches | 80 mils | 64 mils |
| - * Major diameter if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|