APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4499 Issued:2002-03-01
Revised:2019-11-07
Style 4499 Multiconductor Cable with Extruded Non-Integral Jacket

Rating200 deg C, 600 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketXL - See facing page for compound designation
dia of cable under jacket
0.425 inches or less*15 mils min average12 mils minimum at any point
0.426-0.700 dia20 avg16 min
0.701-1.500 dia30 avg24 min
1.501-2.500 dia45 avg36 min
2.501 dia and larger60 avg48 min
*Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of appliances or electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024