Rating | 105 deg C, 30 Vac, Horizontal flame, Cable flame. |
|
Conductor | May use same or mixed AWG size. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. |
|
Jacket | Extruded XLFE - crosslinked floroelastomer - See facing page for compound designation |
| Diameter of cable under jacket | Minimum average | Minimum at any point |
| 0.425 inch or less | 15 mils | 12 mils |
| 0.426-0.700 inch | 20 mils | 16 mils |
| 0.701-1.500 inch | 30 mils | 24 mils |
| 1.501-2.500 inch | 45 mils | 36 mils |
| 2.501 inch and larger | 60 mils | 48 mils |
| *Major diameter if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection or internal wiring of appliances or electronic equipment. |
|