APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4500 Issued:2002-03-28
Revised:2012-01-18
Style 4500 Multiconductor Cable with Extruded Non-integral Jacket

Rating105 deg C, 30 Vac, Horizontal flame, Cable flame.
ConductorMay use same or mixed AWG size.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
JacketExtruded XLFE - crosslinked floroelastomer - See facing page for compound designation
Diameter of cable under jacketMinimum averageMinimum at any point
0.425 inch or less15 mils12 mils
0.426-0.700 inch20 mils16 mils
0.701-1.500 inch30 mils24 mils
1.501-2.500 inch45 mils36 mils
2.501 inch and larger60 mils48 mils
*Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of appliances or electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024