APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4504 Issued:2002-04-11
Revised:2011-07-28
Style 4504 Multiple-Conductor Cable Using Non-Integral Jacket

Rating200 deg C, 300 Vac, Cable flame.
ConductorSolid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketExtruded XLFE - See facing page for compound designation
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.425 inches or less*15 mils12 mils
0.426-0.700 inch20 mils16 mils
0.701-1.500 inch30 mils24 mils
1.501-2.500 inch45 mils36 mils
2.501 inch and larger60 mils48 mils
*Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnect of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024