Rating | 200 deg C, 300 Vac, Cable flame. |
|
Conductor | Solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Jacket | Extruded XLFE - See facing page for compound designation |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.425 inches or less* | 15 mils | 12 mils |
| 0.426-0.700 inch | 20 mils | 16 mils |
| 0.701-1.500 inch | 30 mils | 24 mils |
| 1.501-2.500 inch | 45 mils | 36 mils |
| 2.501 inch and larger | 60 mils | 48 mils |
| *Major diameter if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnect of electronic equipment. |
|