APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4513 Issued:2003-01-27
Revised:2019-11-07
Style 4513 Multiple-conductor cable using non-integral jacketj

Rating90 deg C, 600 Vac, FT2 flame.
Conductor50 AWG - 2000 kcmil solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
CoveringOptional, 4 mil or heavier wall may be extruded over the conductor assembly or groups of conductors. A 1 mil or heavier PETP foil covering may be applied over the conductor assembly.
JacketExtruded NR - NEOPRENE
dia of cable under jacket
0.000-0.750 inches55 mils min average44 mils minimum at any point
0.751-1.000 dia110 avg88 min
1.001-1.250 dia125 avg100 min
1.251-1.500 dia140 avg112 min
1.501-1.750 dia160 avg128 min
1.751-2.000 dia180 avg144 min
2.001-2.250 dia200 avg160 min
2.251-2.500 dia220 avg176 min
2.501-2.750 dia240 avg192 min
2.751-3.000 dia260 avg208 min
3.001-3.250 dia280 avg224 min
3.251-3.500 dia295 avg236 min
3.501-3.950 dia310 avg248 min
3.951-4.450 dia330 avg264 min
4.451-5.000 dia345 avg276 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.