APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4516 Issued:2003-09-12
Revised:2012-05-02
Style 4516 Multiple-conductor cable using non-integral jacket.

Rating150 deg C, 600 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
Assembly2-4 individually insulated conductors twisted together. The length of lay is not specified. Fillers may be used but are not required. Insulated conductor is built with optional inner shield, optional outer shield, and jacket.
ShieldOptional - Insulated singles or conductor assembly may be provided with nylon woven tape with a conductive butyl coating.
JacketExtruded Silicone Rubber, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or External Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024