Rating | 105 deg C, 600 Vac, Horizontal flame, Cable flame. |
|
Conductor | 18 AWG - 4/0 AWG shall be stranded and tinned. Corrosion protected. A fibrous thread may be used within the conductor stranding. May use same or mixed AWG sizes. |
|
Insulation | Extruded EP |
| 18-10 AWG conductor size | 30 mils min average thickness | 27 mils minimum at any point thickness |
| 9-8 AWG | 45 mils | 40 mils |
| 7-2 AWG | 60 mils | 54 mils |
| 1-4/10 AWG | 80 mils | 72 mils |
|
Assembly | Two or more conductors are twisted together. Fillers required in order to forming cable round. Individual insulated conductor and/or core assembly may be optionally wrapped with a fabric. |
|
Shield | Optional. |
|
Jacket | Extruded PVC |
| dia of cable under jacket |
| 0-1.500 inches | 60 mils min average thickness | 48 mils minimum at any point thickness |
| 1.501-2.500 inches dia | 80 mils | 64 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external wiring of Appliances or Electronic Equipment. |
|