APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4528 Issued:2004-11-17
Revised:2019-11-07
Style 4528 Muticonductor Cable with Extruded Non-Integral Jacket

Rating105 deg C, 600 Vac, Horizontal flame, Cable flame.
Conductor18 AWG - 4/0 AWG shall be stranded and tinned. Corrosion protected. A fibrous thread may be used within the conductor stranding. May use same or mixed AWG sizes.
InsulationExtruded EP
18-10 AWG conductor size30 mils min average thickness27 mils minimum at any point thickness
9-8 AWG45 mils40 mils
7-2 AWG60 mils54 mils
1-4/10 AWG80 mils72 mils
AssemblyTwo or more conductors are twisted together. Fillers required in order to forming cable round. Individual insulated conductor and/or core assembly may be optionally wrapped with a fabric.
ShieldOptional.
JacketExtruded PVC
dia of cable under jacket
0-1.500 inches60 mils min average thickness48 mils minimum at any point thickness
1.501-2.500 inches dia80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external wiring of Appliances or Electronic Equipment.