Rating | 90 deg C, 1000 Vac, Horizontal flame. |
|
Insulation | Labeled or complying with Manufacturer's AWM procedure having a minimum rating of 90 deg C, 1000 Vac. |
|
Covering | Optional, EPDM, may be extruded over the conductor assembly or groups of conductors, 4 mils minimum thickness. |
|
Covering | Optional, PETP foil may be applied over the conductor assembly, 1 mil minimum thickness. |
|
Shield | Optional. |
|
Binder | Optional, PETP foil and cotton tape, may be applied over Shield. |
|
Jacket | Extruded CPE. |
| Calculated diameter under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.000 - 0.750 inch or 0.00 - 19.05 mm | 55 mils or 1.40 mm | 44 mils or 1.12 mm |
| 0.751 - 1.000 inch or 19.08 - 25.40 mm | 110 mils or 2.79 mm | 88 mils or 2.24 mm |
| 1.001 - 1.250 inch or 25.43 - 31.75 mm | 125 mils or 3.18 mm | 100 mils or 2.54 mm |
| 1.251 - 1.500 inch or 31.78 - 38.10 mm | 140 mils or 3.36 mm | 112 mils or 2.84 mm |
| 1.501 - 1.750 inch or 38.13 - 44.45 mm | 160 mils or 4.06 mm | 128 mils or 3.25 mm |
| 1.751 - 2.000 inch or 44.48 - 50.80 mm | 180 mils or 4.57 mm | 144 mils or 3.66 mm |
| 2.001 - 2.250 inch or 50.83 - 57.15 mm | 200 mils or 5.08 mm | 160 mils or 4.06 mm |
| 2.251 - 2.500 inch or 57.18 - 63.50 mm | 220 mils or 5.59 mm | 176 mils or 4.47 mm |
| 2.501 - 2.750 inch or 63.53 - 69.85 mm | 240 mils or 6.10 mm | 192 mils or 4.88 mm |
| 2.751 - 3.000 inch or 69.88 - 76.20 mm | 260 mils or 6.60 mm | 208 mils or 5.28 mm |
| 3.001 - 3.250 inch or 76.23 - 82.55 mm | 280 mils or 7.11 mm | 224 mils or 5.69 mm |
| 3.251 - 3.500 inch or 82.58 - 88.90 mm | 295 mils or 7.49 mm | 236 mils or 5.99 mm |
| 3.501 - 3.950 inch or 88.93 - 100.33 mm | 310 mils or 7.87 mm | 248 mils or 6.30 mm |
| 3.951 - 4.450 inch or 100.36 - 113.03 mm | 330 mils or 8.38 mm | 264 mils or 6.71 mm |
| 4.451 - 5.000 inch or 113.06 - 127.00 mm | 345 mils or 8.76 mm | 276 mils or 7.01 mm |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|