APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4542 Issued:2007-06-13
Revised:2011-10-25
Style 4542 Multiple conductor with extruded insulation and extruded non-integral jacket

Rating150 deg C, 300 Vac, Horizontal flame. Optional - -40 deg C.
Conductor50 AWG - 15 AWG, stranded, Resistance Heater Wire.
InsulationExtruded XLPO, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyTwo insulated conductors twisted together to form a round or oval cable.
ShieldWire braid, tinned copper, 95% coverage.
JacketExtruded XLPO, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring; Resistance Heater Wire.

UL and the UL Logo are trademarks of UL LLC © 2024