APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4554 Issued:2009-07-09
Revised:2012-12-11
Style 4554 Single Conductor with extruded insulation

Rating80 deg C, 125 Vac, Horizontal flame.
Inner Conductor39-29 AWG, solid or stranded, spirally wound around a glass, polyester or Aramid fiber core.
Inner InsulationExtruded Silicone Rubber, 20 mils minimum average thickness, 18 mils minimum thickness at any point.
Middle Conductor39-29 AWG, solid or stranded.
Middle InsulationExtruded Nylon, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
Outer Conductor39-29 AWG, solid or stranded.
Outer InsulationExtruded PVC, 20 mils minimum average thickness, 18 mils minimum thickness at any point.
AssemblyInner Conductor covered by Inner Insulation. Middle Conductor spirally wound around Inner Insulation and covered by Middle Insulation. Outer Conductor spirally wound around Middle Insulation and covered by Outer Insulation.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024