| Rating | 80 deg C, 125 Vac, Horizontal flame. |
|
| Inner Conductor | 39-29 AWG, solid or stranded, spirally wound around a glass, polyester or Aramid fiber core.
|
|
| Inner Insulation | Extruded Silicone Rubber, 20 mils minimum average thickness, 18 mils minimum thickness at any point. |
|
| Middle Conductor | 39-29 AWG, solid or stranded. |
|
| Middle Insulation | Extruded Nylon, 12 mils minimum average thickness, 10 mils minimum thickness at any point. |
|
| Outer Conductor | 39-29 AWG, solid or stranded. |
|
| Outer Insulation | Extruded PVC, 20 mils minimum average thickness, 18 mils minimum thickness at any point.
|
|
| Assembly | Inner Conductor covered by Inner Insulation. Middle Conductor spirally wound around Inner Insulation and covered by Middle Insulation. Outer Conductor spirally wound around Middle Insulation and covered by Outer Insulation. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring. |
|