Rating | 80 deg C, 125 Vac, Horizontal flame. |
|
Inner Conductor | 39-29 AWG, solid or stranded, spirally wound around a glass, polyester or Aramid fiber core.
|
|
Inner Insulation | Extruded Silicone Rubber, 20 mils minimum average thickness, 18 mils minimum thickness at any point. |
|
Middle Conductor | 39-29 AWG, solid or stranded. |
|
Middle Insulation | Extruded Nylon, 12 mils minimum average thickness, 10 mils minimum thickness at any point. |
|
Outer Conductor | 39-29 AWG, solid or stranded. |
|
Outer Insulation | Extruded PVC, 20 mils minimum average thickness, 18 mils minimum thickness at any point.
|
|
Assembly | Inner Conductor covered by Inner Insulation. Middle Conductor spirally wound around Inner Insulation and covered by Middle Insulation. Outer Conductor spirally wound around Middle Insulation and covered by Outer Insulation. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|