Rating | 90 deg C, 1000 Vac, Cable flame, Optional - 60 deg C Oil |
|
Conductor | 30 AWG - 2000 kcmil solid or stranded |
|
Insulation | Extruded EPDM, 30 mils minimum average thickness, 27 mils minimum thickness at any point |
|
Shield | Optional |
|
Covering | Optional - non-extruded - 1 mil or heavier PET, PETP tape may be applied over the conductor assembly |
|
Jacket | Extruded CP or CPE |
| Diameter (inches) | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.000-0.0700 | 33 | 26 |
| 0.701-1.000 | 45 | 36 |
| 1.001-1.500 | 60 | 48 |
| 1.501-2.500 | 80 | 64 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General |
|
Use | External Interconnection of appliances |
|