APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4557 Issued:2009-07-23
Revised:2011-07-28
Style 4557 Multiconductor Cable with Extruded Insulation and Extruded Non-integral Jacket

Rating90 deg C, 1000 Vac, Horizontal flame, Optional - 60 deg C Oil
Conductor30 AWG - 2000 kcmil solid or stranded
InsulationExtruded EPDM, 30 mils minimum average thickness, 27 mils minimum thickness at any point
ShieldOptional
CoveringOptional - non-extruded - 1 mil or heavier PET, PETP tape may be applied over the conductor assembly
JacketExtruded CP or extruded CPE, 33 mils minimum average thickness, 26 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal wiring of appliances

UL and the UL Logo are trademarks of UL LLC © 2024