APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4568 Issued:2010-05-07
Revised:2010-05-12
Style 4568 Flat Cable.

Rating105 deg C, 90 Vac Horizontal flame.
Conductor44 AWG - 24 AWG, solid or stranded round.
InsulationXLPE, 3 mils minimum average thickness, 2 mils minimum thickness at any point, 9 mils minimum distance between conductors.
AssemblyFlat cable employing 2 - 100 conductors, insulation extruded simultaneously over conductors laid parallel, non-separable construction.
ShieldOptional. Metal clad PET tape laminated on either or both major axis side of flat cable core with polyester adhesive.
CoveringMetal clad PET tape. Wrapped longitudinally and sealed by polyester adhesive. Minimum 0.8 mils for composite covering thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.
 