APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4573 Issued:2010-10-05
Revised:2011-10-12
Style 4573 Multiconductor Cable with Extruded Non-integral Jacket

Rating90 deg C, 300 V, Horizontal flame.
Conductor50-10 AWG, Solid or stranded round.
InsulationExtrueded TPES, 9 mils minimum average thickness, 8 mils minimum thickness at any point. See Facing Page for Compound Designation.
AssemblyTwo insulated conductors laid parallel or two or more insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldMetal tape or braid provided under the overall jacket.
JacketXLPE - CHEM Or IRR, 13 mils min average, 10 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances.