APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4575 Issued:2010-10-05
Revised:2011-08-01
Style 4575 Multiple-conductor cable using non-intergral jacket.

Rating90 deg C, 300 V, No Flame Rating.
Conductor50 AWG - 10 AWG min. solid or stranded.
InsulationExtruded ETFE, 9 mils minimum average thickness, 8 mils minimum thickness at any point.
AssemblyTwo insulated conductors laid parallel or two or more insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional - Metal Tape or Metal Braid.
JacketExtruded XLPE, 13 mils minimum average thickness, 10 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing as Resistance Heater Wire where the acceptability has been determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024