APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4576 Issued:2010-10-20
Revised:2011-09-20
Style 4576 Multiconductor Cable with Extruded Non-Integral Jacket

Rating90 deg C, 300 V, No Flame Rating.
Conductor50 AWG - 10 AWG min. solid or stranded round.
InsulationTPES - THERMOPLASTIC POLYESTER, 9 mils min average, 8 mils min at any point. See Facing Page for Compound.
AssemblyTwo insulated conductors laid parallel or two or more insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional - A metal braid and/or a metal tape shield may be provided under the jacket.
JacketXLFRPE - CHEM Or IRR, 13 mils min average, 10 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing as Resistance Heater Wire where the acceptability has been determined by Underwriters Laboratories Inc..

UL and the UL Logo are trademarks of UL LLC © 2024