| Rating | 105 deg C, 30 Vac Horizontal flame. |
|
| Conductor | Solid or stranded round. |
|
| Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
| Assembly | Two or more insulated conductors. Manufacturer shall maintain a complete description of each assembly. |
|
| Shield | Optional. |
|
| Covering | Optional inner layer. |
|
| Jacket | Extruded XLPE - Chemical Or Irradiated, 15 mils min average, 12 mils minimum at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring of appliances. |
|