APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4580 Issued:2011-01-14
Revised:2011-07-28
Style 4580 Parallel Cable with Extruded Integral Insulation

Rating105 deg C, 30 Vac, Horizontal flame
Conductor40 AWG - 10 AWG min, solid or stranded
InsulationExtruded XLPE, 4 mils minimum average thickness, 3 mils minimum thickness at any point
Assembly2 to 150 insulated conductors are co-extruded in such a fashion to form a rippable flat ribbon-type cable. All conductors in any one cable may be of the same AWG size or mixed AWG sizes. Thickness before and after ripping shall be 4 mils min average thickness, 3 mils min thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal wiring of appliances where not subjected to movement or mechanical damage.