APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4588 Issued:2013-06-28
Revised:New
Style 4588 Multiple-conductor Cable using Non-Integral Jacket

Rating150 deg C,600 Vac.
Conductor40 AWG minimum, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional, manufacturer shall maintain a complete description of each assembly.
ShieldOptional - May be over one or more of the insulated conductors or applied over the assembly.
JacketExtruded SR.
Dia of cable under jacketMinimum average thicknessMinimum thickness at any point
0.425 inch or less39 mils30 mils
0.426-0.700 inch45 mils36 mils
0.701-1.500 inch60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring and/or External Wiring; No Flame Rating.

UL and the UL Logo are trademarks of UL LLC © 2024