APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4594 Issued:2014-04-04
Revised:2014-04-09
Style 4594 Multiple conductor with extruded non-integral jacket

Rating200 deg C,600 Vac Horizontal flame.
Conductor30 AWG - 2000 kcmil, solid or stranded..
InsulationExtruded SR - Silicone Rubber, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketExtruded SR - Silicone Rubber, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.