APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4607 Issued:2015-01-30
Revised:2015-02-03
Style 4607 Multiple-COnductor Cable using Non-Integral Jacket.

Rating125 deg C,no voltage specified, Cable flame.
Conductor50 AWG - 2 AWG, solid or stranded.
InsulationLabeled Style 5551.
AssemblyTwo or more singles, twisted pairs or groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketSR, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.