APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4609 Issued:2015-04-08
Revised:New
Style 4609 Multiple-conductor with extruded non-integral jacket

Rating200 deg C,300 Vac Horizontal flame.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional, Glass braid with varnish.
ShieldOptional.
JacketExtruded SR - Silicone Rubber, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024