APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4613 Issued:2015-01-22
Revised:2016-01-26
Style 4613 Multi-conductor cable with extruded non-integral jacket

Rating90 deg C, -40 deg C, 150 Vac, Cable flame.
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationExtruded XLPE with 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyTwo or more singles or groups of twisted singles twisted together. Lay not specified. Barrier layers, tape(s) and/or fillers optional.
ShieldOptional.
CoveringOptional.
JacketExtruded Thermoset CPE (See Facing Page for Compound)
Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024