APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4615 Issued:2016-10-27
Revised:New
Style 4615 Mutli Conductor Cable using Non-Integral Jacket

Rating150 deg C, 300 Vac, Horizontal Flame.
Conductor50 AWG - 19 AWG, Stranded Metal Coated
InsulationLabeled AWM or complying with Manufacturer's AWM procedure
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
JacketExtruded SR - 24 mils min. avg., 19 mils min. at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024