Rating | 150 deg C,1000 Vac Cable flame. |
|
Conductor | 40 AWG minimum, solid or stranded. |
|
Insulation | Labeled, complying with Manufacturer's AWM Procedure, rated 150C, 1000V minimum. |
|
Assembly | Consists of two or more insulated conductors, or groups of insulated conductors, cabled together forming oval or round cable. The lay of cabled conductors is not specified. Insulated conductors or groups of insulated singles may also be laid parallel to form a flat cable. Fillers optional. Manufacturer shall maintain a complete description of each assembly. May use the same or mixed AWG size. |
|
Shield | Optional. One or more shields may be provided. |
|
Covering | Optional. Extruded FEP or PFA or non-extruded PTFE Tape or Polyimide Tape. May be applied over single insulated conductors, groups of insulated conductors and/or the entire cable assembly. The covering may be provided under the jacket or it may be provied under or over the shield, when provided. |
|
Jacket | Extruded SR |
| Diameter of cable under jacket in inches | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.700 or less | 30 | 24 |
| 0.701-1.000 | 45 | 36 |
| 1.001-1.500 | 60 | 48 |
| 1.501-2.500 | 80 | 64 |
| 2.501-4.000 | 110 | 88 |
| 4.001 and larger | 140 | 112 |
| Major diameter if cable is flat or oval. Jacket may be extruded in two layers with a textile braid between the layers. The thickness of the individual layers is not specified.# Major diameter if cable is flat or oval. Jacket may be extruded in two layers with a textile braid between the layers. The thickness of the individual layers is not specified. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|