APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4618 Issued:2017-05-08
Revised:2018-07-11
Style 4618 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating150 deg C,1000 Vac Cable flame.
Conductor40 AWG minimum, solid or stranded.
InsulationLabeled, complying with Manufacturer's AWM Procedure, rated 150C, 1000V minimum.
AssemblyConsists of two or more insulated conductors, or groups of insulated conductors, cabled together forming oval or round cable. The lay of cabled conductors is not specified. Insulated conductors or groups of insulated singles may also be laid parallel to form a flat cable. Fillers optional. Manufacturer shall maintain a complete description of each assembly. May use the same or mixed AWG size.
ShieldOptional. One or more shields may be provided.
CoveringOptional. Extruded FEP or PFA or non-extruded PTFE Tape or Polyimide Tape. May be applied over single insulated conductors, groups of insulated conductors and/or the entire cable assembly. The covering may be provided under the jacket or it may be provied under or over the shield, when provided.
JacketExtruded SR
Diameter of cable under jacket in inchesMinimum average thickness (mils)Minimum thickness at any point (mils)
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
2.501-4.00011088
4.001 and larger140112
Major diameter if cable is flat or oval. Jacket may be extruded in two layers with a textile braid between the layers. The thickness of the individual layers is not specified.# Major diameter if cable is flat or oval. Jacket may be extruded in two layers with a textile braid between the layers. The thickness of the individual layers is not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.