APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4623 Issued:2018-08-02
Revised:2018-08-07
Style 4623 Multiconductor Cable with Extruded Non-Integral Jacket

Rating125 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more insulated singles, twisted pairs or groups of twisted singles twisted together or singles or groups of singles may be laid parallel to from flat, oval or round cable. A barrier layer and/or fillers are optional. May use same or mized AWM size.
ShieldOptional.
CoveringOptional. May be provided under or over the shield.
JacketExtruded XLPE, 14 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024