APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4624 Issued:2018-08-02
Revised:2018-08-07
Style 4624 Multiple-Conductor Cable using Non-Integral Jacket

Rating125 deg C,300 Vac Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more insulated singles, twisted pairs or groups of twisted singles twisted together or singles or groups of singles may be laid parallel to from flat, oval or round cable. A barrier layer and/or fillers are optional. May use same or mixed AWM size.
ShieldOptional
CoveringOptional. May be provided under or over the shield.
JacketExtruded XLPE, 14 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.