APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4629 Issued:2018-11-01
Revised:New
Style 4629 Multiple-conductors cable using non-integral jacket.

Rating105 deg C, 15000 Vac, Horizontal flame.
Conductor26 AWG - 14 AWG, solid or stranded.
InsulationExtruded XLPE, 94 mils minimum average thickness, 85 mils minimum thickness at any point.
AssemblyTwo or more conductors, twisted pairs, or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction. Barrier layer, tapes and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly.
Inner JacketExtruded PVC, 39 mils minimum average thickness, 31 mils minimum thickness at any point, extruded over each insulated conductor.
ShieldOptional.
CoveringOptional.
JacketExtruded PVC.
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
1.500 or less7056
1.501-2.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024