APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4633 Issued:2019-02-14
Revised:New
Style 4633 Multiple-conductor cable using non-integral jacket.

Rating150 deg C, 30 or 125 Vac, Horizontal flame.
InsulationLabeled or complying with Manufacturer's AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers and/or kevlar strength members are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional - Metal braid, metal tape or an aluminum/polyester tape.
JacketExtruded SR, 30 mils min average thickness, 27 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial - Interconnecting cable for medical instruments - where the acceptability of the combination is to be determined by Underwriters Laboratories.