APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4634 Issued:2019-02-19
Revised:2020-04-03
Style 4634 Multiple Conductor Cable with Extruded Non-Integral Jacket

Rating105 deg C, 300 Vac, Horizontal Flame.
InsulationLabeled Style 11798 or Complying with Manufacturers AWM Procedure
AssemblyConsists of two or more conductors, twisted pairs, or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional - Metallic Braid
CoveringOptional
JacketExtruded SR - 12 mils minimum average thickness, 10 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.