APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4636 Issued:2019-03-06
Revised:2019-03-28
Style 4636 Multiple-conductor cable using non-intergral jacket.

Rating90 deg C, 300 Vac, Horizontal Flame.
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationExtruded XLPE, 12 mils minimum average thickness, 10 mils minimum thickness at any point
AssemblyTwo insulated conductors laid parallel or two or more insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional - Metal Tape or Metal Braid.
JacketExtruded XLPE, 13 mils minimum average thickness, 10 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024