APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4641 Issued:2020-11-18
Revised:2020-11-19
Style 4641 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 300 Vac, Horizontal flame.
Insulated ConductorLabeled or complying with Manufacturer's AWM Procedure. 40 AWG minimum.
AssemblyConsists of two or more singles, twisted pairs or groups of twisted singles twisted together. The singles or groups of singles may be laid parallel forming a flat, oval or round cable. The lay of the conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional.
ShieldOptional.
JacketExtruded CPE, 11 mils minimum average thickness, 8 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024