APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4646 Issued:2021-07-13
Revised:2021-07-19
Style 4646 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 30 Vdc or 30 Vac, Cable flame, VW-1 flame.
Insulated conductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more insulated conductors with shield(s), jacket and polyester braid. Fillers and binder tapes may be employed.
ShieldOne or more metal tapes or braids provided under the extruded jacket.
JacketExtruded Silicone Rubber, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
CoveringNon-metallic Braid consisting of polyester fiber yarns.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial-For use with information technology equipment where the acceptability of the combination is to be determined by UL LLC or in the end use application.

UL and the UL Logo are trademarks of UL LLC © 2024