APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4647 Issued:2021-07-20
Revised:2021-07-21
Style 4647 Flat ribbon cable

Rating105 deg C, 600 Vac, Horizontal flame.
Conductor50 AWG - 8 AWG, solid or stranded.
InsulationExtruded XLPE, 6 mils minimum average thickness, 5 mils minimum thickness at any point.
AssemblyTwo or more insulated conductors laid parallel to form a flat cable. Insulation may be extruded simultaneously over multiconductors, or individually to form insulated singles laid parallel and heat-bonded together. May use same or mixed AWG size.
ShieldOptional.
JacketOptional, extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.