|
Rating | 150 deg C, 600 Vac, Cable flame. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more conductors, twisted pairs, or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction. Barrier layer, tapes and/or fillers are optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly. |
|
Shield | Optional. |
|
Covering | Optional. |
|
Jacket | Extruded XLFE (Crosslinked Fluoroelastomer). See Facing Page for compound designation. |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 2.500 inch or less | 30 mils | 24 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|