APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4658 Issued:2023-06-26
Revised:New
Style 4658 Multiple Conductor Cable using Non-Integral Extruded Jacket

Rating80 deg C, 300 Vac, Cable Flame
Conductor22 AWG - 12 AWG, Stranded Metal Coated Copper
InsulationExtruded PP - 10 mils minimum average thickness, 9 mils minimum at any point or Extruded PVC - 32 mils minimum average thickness, 29 mils minimum average thickness.
AssemblyOne or more pairs of PP insulation with barrier, metal coated drain wire, and AL/Polyester Foil Shield. One or more PVC insulated conductors. PP and or Kevlar Fillers and PP Binder. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly.
JacketExtruded CPE
diameter of round assembly under jacket in inchesaverage thickness in milsminimum thickness in mils
0-1.5006048
1.5001-2.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2025