APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4659 Issued:2024-01-08
Revised:2024-02-15
Style 4659 Multiple-conductor cable using non-integral jacket

Rating150 deg C, 3000 Vac, Cable flame.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure with minimum ratings of 150C, 3000Vac.
AssemblyTwo or more conductors. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional.
ShieldOptional.
JacketExtruded SR.
Diameter of core assembly under jacket (Inches)Minimum average thickness (Mils)Minimum thickness at any point (Mils)
0.700 or less5544
0.701 - 1.0006048
1.001 - 1.5008064
1.501 - 2.50011088
2.501 - 3.500140112
3.500 or larger160128
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024