APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5034 Issued:1959-05-01
Revised:2012-03-08
Style 5034 Single conductor with other-than-extruded insulation

Rating200 deg C, 600 Vac, Horizontal flame.
Conductor24 AWG - 16 AWG, solid or stranded round
InsulationPTFE tape applied with approximately 50 percent overlap, 15 mils minimum average thickness, 14 mils minimum thickness at any point
CoveringGlass braid, approximately 5 mils minimum thickness, impregnated with a silicone electrical varnish
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.