APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5045 Issued:1960-09-09
Revised:2011-12-06
Style 5045 Single conductor with non-extruded insulation and non-extruded covering.

Rating150 deg C, 600 Vac, Horizontal flame.
Conductor24 AWG - 20 AWG solid or stranded.
InsulationOne or more PTFE tapes applied with approximately 50 percent overlap. 15 mils min average thickness.
CoveringGlass braid, approximately 5 mils thick, impregnated with a silicone electrical varnish.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024