|
Rating | 105 deg C, 600 Vac. |
|
Conductor | 20 AWG - 8 AWG consisting of Nos. 30-38 AWG stranded. Length of lay per requirements for Type ST Cord. |
|
Insulation | PTFE tape, 2.0 mils thickness applied half-lap directly beneath a PETP tape, 0.5 mils thickness applied half lap, the tapes to lie between inner and outer closely woven PETP fiber braids. |
|
Assembly | Insulated single conductor. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Wire within hermetic motors where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|