APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5058 Issued:1963-06-04
Revised:2011-12-02
Style 5058 Single conductor with other-than-extruded insulation

Rating105 deg C, 600 Vac.
Conductor20 AWG - 8 AWG consisting of Nos. 30-38 AWG stranded. Length of lay per requirements for Type ST Cord.
InsulationPTFE tape, 2.0 mils thickness applied half-lap directly beneath a PETP tape, 0.5 mils thickness applied half lap, the tapes to lie between inner and outer closely woven PETP fiber braids.
AssemblyInsulated single conductor.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWire within hermetic motors where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.