APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5097 Issued:1970-12-03
Revised:2012-05-15
Style 5097 Single Conductor with Non-extruded Insulation.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor1.25 sq. mm - 0.500 sq. mm, stranded bare copper.
Insulation1 st layer - PET treads. 2nd layer - PET tape, 0.02 mm minimum thickness, 9.0 mm mimimum width. 3rd layer - PET braid.
AssemblyServing of oriented PET threads held in place with oriented PET tape wound spirally over the threads, having a minimum overlap of 50%. And then covered with an outer braid of PET consisting of 16 ends, each containing three threads.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024