APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5122 Issued:1973-05-22
Revised:2012-07-25
Style 5122 Single conductor with other-than-extruded insulation

Rating90 deg C, 150 Vac, Horizontal flame, Oil Resistant 60 deg C (optional).
Conductor32 AWG - 20 AWG solid or stranded.
InsulationLaminated Tape with Oriented Polyethylene Terephthalate and Polyester or PVC Adhesive in 4.0 mil min. avg. and 3.0 mil min. at any point wall in the form of a spiral wrap bonded together.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring where not subjected to movement of mechanical damage and may be exposed to oil not exceeding 60 deg C.Tags may indicate the following: "300 volts For Electronic Use Only".

UL and the UL Logo are trademarks of UL LLC © 2024