Rating | 450 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 24 AWG - 4 AWG, solid or stranded. |
|
Insulation | Non-extruded Mica tape (see below), or Mica composite (see facing page). |
| Conductor AWG size | Min Avg. thickness of total Mica tape layers (mils) | Min Avg. thickness of Glass braid treated with Silicone Varnish or TFE Finish (mils) |
| 24 - 12 | 15 | 7 |
| 11 - 4 | 20 | 15 |
|
Shield | Optional. Stainless steel, alloy 304, applied as a braid over the treated glass braid. |
|
Assembly | Optional, two or more conductors described above, may be cabled together with a max O.D. of 1.500 inches. A Mica glass binder and/or fiberglass fillers may be employed. The assembly may have an overall treated glass braid. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of high-temperature equipment where not subjected to repeated flexing and protected from mechanical abuse. (The acceptability, including current-carrying capacity, has been determined by Underwriters Laboratories Inc.). |
|