			| Rating | 250 deg C, 300 Vac, Horizontal Flame. | 
		
			 | 
		
			| Conductor | 22 AWG - 4 AWG.  Solid or stranded for 22 AWG - 8 AWG; Stranded only for larger sizes than 8 AWG. | 
		
			 | 
		
			| Insulation | Nonextruded Mica tape with braid. | 
		
			 | Conductor size | Min average thickness of total Mica tape layers | Min average of Glass Braid Treated with Silicone Varnish or TFE Finish | 
		
			 | 22 - 12 AWG | 15 mils | 7 mils | 
		
			 | 11 - 4 AWG | 20 mils | 15 mils | 
		
			 | 
		
			| Standard | Appliance Wiring Material UL 758. | 
		
			 | 
		
			| Marking | General. | 
		
			 | 
		
			| Use | Internal Wiring | 
		
			 |