APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5137 Issued:1974-09-17
Revised:2012-07-26
Style 5137 Single conductor with other than extruded insulation.

Rating105 deg C, 600 Vac.
Conductor20 AWG - 4 AWG, consisting of 38-30 AWG strands, length of lay of conductors per requirements for Type ST Cord.
InsulationConsists of an inner closely woven Polyester braid; one PTFE tape, approximately 2.0 mils thick; and one Polyester tape, approximately 0.5 mil thick; each tape is minimum 0.5 inch wide and is applied with a minimum 0.5 overlap. Over this assembly an outer closely woven Polyester braid is applied.
AssemblyInsulated single conductor.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseLead wire within Hermetic Motors where the acceptability of the combination is to be determined by UL LLC.

UL and the UL Logo are trademarks of UL LLC © 2024