Rating | 250 deg C, 125 Vac. |
|
Conductor | 1 to 11 mil diameter resistance wire wound spirally with at least 20 turns per inch. |
|
Insulation | FIBERGLASS, 2 mils minimum average thickness. Four layers of wrapped glass Fiber, each successive layer wound in opposite direction. |
|
Covering | Glass Fiber braid; 22 - 28 picks per inch, 16 - 20 carriers, covered with Silicone Varnish. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Heating Appliances. |
|