APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5140 Issued:1975-06-19
Revised:2012-03-28
Style 5140 Single Conductor with Other-Than-Extruded Insulation and Covering

Rating250 deg C, 125 Vac.
Conductor1 to 11 mil diameter resistance wire wound spirally with at least 20 turns per inch.
InsulationFIBERGLASS, 2 mils minimum average thickness. Four layers of wrapped glass Fiber, each successive layer wound in opposite direction.
CoveringGlass Fiber braid; 22 - 28 picks per inch, 16 - 20 carriers, covered with Silicone Varnish.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Heating Appliances.