APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5154 Issued:1977-03-14
Revised:2011-10-31
Style 5154 Single conductor with other-than-extruded insulation

Rating350 deg C, 125 Vac, Horizontal flame.
Conductor50 - 30 AWG, nickel plated copper, nickel-chromium alloy.
InsulationFIBERGLASS, 2 mils min average.
AssemblyConductor wound spirally with at least 20 turns per inch on a glass fiber core.
Covering(A). Inner - A Fiberglas braid; 8 to 12 picks per inch and 20 carriers. Outer - A Fiberglas braid; 20 to 23 picks per Inch and 20 carriers. or (B). Inner - A Fiberglas braid; 8 to 12 picks per inch and 16 carriers. Outer - Two Fiberglas braids; 20 to 23 picks per inch and 16 carriers. or (C). Inner - A Fiberglas braid; 8 to 12 picks per inch and 20 carriers. Outer - A Fiberglas braid; 18 to 22 picks per inch and 20 carriers.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024