APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5159 Issued:1977-08-29
Revised:2012-07-16
Style 5159 Single conductor with other-than-extruded insulation

Rating105 deg C, Voltage not specified, Horizontal flame, Oil Resistant 60 deg C (optional).
Conductor32 AWG - 20 AWG solid or stranded round, tinned or bare copper.
InsulationOriented Polyethylene Terephthalate tape with Polyester in nominal 3.5 mil and min. 3.0 mil wall in the form of a spiral wrap bonded together.
CoveringExpanded PTFE (Taped or Extruded Polytetrofluoroethylene) 0.5 mil min. at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring where not subjected to movement or mechanical damage. Tags may indicate the following: "Where exposed to oil not exceeding 60 deg C."