APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5162 Issued:1977-08-30
Revised:2012-07-07
Style 5162 Single conductor wire using other-than-extruded jacket or non-integral jacket.

Rating105 deg C, 30 Vac, Horizontal flame.
Conductor36 AWG - 20 AWG, solid or stranded.
InsulationNon-extruded Foamed PTFE tape, 4 mils minimum thickness at any point.
ShieldOptional.
JacketNon-extruded Oriented PETP film laminated with Polyester or PVC adhesive, 4 mils minimum thickness at any point. Or Extruded FEP, 6 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment in Class 2 circuits only.

UL and the UL Logo are trademarks of UL LLC © 2025